Abhijit Kshirsagar
2 years ago
1 changed files with 29 additions and 0 deletions
@ -0,0 +1,29 @@ |
|||||
|
Name Pramod Reddy |
||||
|
|
||||
|
1. Question text: |
||||
|
Amonia Sensor |
||||
|
|
||||
|
2. Design summary: |
||||
|
Fairly well written. |
||||
|
Your worst case design is ok. |
||||
|
Could have added a calibration step / method to calibrate at known gas conc. |
||||
|
What happens if there is a problem with the sensor? The clean air level |
||||
|
should fall below 2mV and that should trigger a different warning/alarm also. |
||||
|
|
||||
|
3. Block diagram |
||||
|
|
||||
|
4. Power supply design |
||||
|
|
||||
|
5. Industrial Design: |
||||
|
|
||||
|
6. KICAD Design |
||||
|
Schematic: |
||||
|
Circuit design is ok overall. Could have added more functionality |
||||
|
|
||||
|
PCB: |
||||
|
Layout is too loose. |
||||
|
Transformer need not be board mounted - too much weight. |
||||
|
If all your components are SMD layout could be tighter. |
||||
|
|
||||
|
7. Pricing / BOM / Assembly |
||||
|
Final prixing? |
Loading…
Reference in new issue