Name Hemanth
|
||||
|
||||
1. Question text:
|
||||
iHumidity Sensor / plants
|
||||
|
||||
2. Design summary:
|
||||
Overall is ok- needs more details of how each component integrates.
|
||||
For example the idea of switching off the buzzer by the attending person is good - how is it implemented?
|
||||
That should have been shown in the block diagram!
|
||||
|
||||
3. Block diagram
|
||||
Se above
|
||||
|
||||
4. Power supply design
|
||||
Your power supply design assumes 2mA of sensor current but that is not necessarily the case.
|
||||
Your supply is basically open loop and any change in batery voltage will cause change in sensor supply!
|
||||
|
||||
5. Industrial Design:
|
||||
Not detailed enough!
|
||||
|
||||
6. KICAD Design
|
||||
Schematic:
|
||||
Diode D1 is backwards - your design will never get power.
|
||||
The Opamp is conneced to a unipolar supply - it will not be able to sink current to drive the buzzer!
|
||||
|
||||
PCB:
|
||||
Layout looks good.
|
||||
|
||||
7. Pricing / BOM / Assembly
|
||||
Your bom sheet has a "risk rate" number. What is that?
|
||||
|