Name Pramod Reddy
|
||||||
|
|
||||||
|
1. Question text:
|
||||||
|
Amonia Sensor
|
||||||
|
|
||||||
|
2. Design summary:
|
||||||
|
Fairly well written.
|
||||||
|
Your worst case design is ok.
|
||||||
|
Could have added a calibration step / method to calibrate at known gas conc.
|
||||||
|
What happens if there is a problem with the sensor? The clean air level
|
||||||
|
should fall below 2mV and that should trigger a different warning/alarm also.
|
||||||
|
|
||||||
|
3. Block diagram
|
||||||
|
|
||||||
|
4. Power supply design
|
||||||
|
|
||||||
|
5. Industrial Design:
|
||||||
|
|
||||||
|
6. KICAD Design
|
||||||
|
Schematic:
|
||||||
|
Circuit design is ok overall. Could have added more functionality
|
||||||
|
|
||||||
|
PCB:
|
||||||
|
Layout is too loose.
|
||||||
|
Transformer need not be board mounted - too much weight.
|
||||||
|
If all your components are SMD layout could be tighter.
|
||||||
|
|
||||||
|
7. Pricing / BOM / Assembly
|
||||||
|
Final prixing?
|
Loading…