Name Pramod Reddy
|
||||
|
||||
1. Question text:
|
||||
Amonia Sensor
|
||||
|
||||
2. Design summary:
|
||||
Fairly well written.
|
||||
Your worst case design is ok.
|
||||
Could have added a calibration step / method to calibrate at known gas conc.
|
||||
What happens if there is a problem with the sensor? The clean air level
|
||||
should fall below 2mV and that should trigger a different warning/alarm also.
|
||||
|
||||
3. Block diagram
|
||||
|
||||
4. Power supply design
|
||||
|
||||
5. Industrial Design:
|
||||
|
||||
6. KICAD Design
|
||||
Schematic:
|
||||
Circuit design is ok overall. Could have added more functionality
|
||||
|
||||
PCB:
|
||||
Layout is too loose.
|
||||
Transformer need not be board mounted - too much weight.
|
||||
If all your components are SMD layout could be tighter.
|
||||
|
||||
7. Pricing / BOM / Assembly
|
||||
Final prixing?
|