Name Shreya
|
||
|
|
||
|
1. Question text:
|
||
|
Ammonia
|
||
|
|
||
|
2. Design summary:
|
||
|
Design summary has only the basic circuit design.. I do not see the discussion of constraints, tradeoffs, etc.
|
||
|
Also, there are ~20 sensors and one control unit / control room. How are you integrating them all?
|
||
|
|
||
|
|
||
|
3. Block diagram
|
||
|
Overall aproach is ok - does not meet requirement as mentioned above.
|
||
|
|
||
|
|
||
|
4. Power supply design
|
||
|
Why is a 3A supply needed?
|
||
|
at that power why not go for a power brick?
|
||
|
Linear supply is too inefficient!
|
||
|
|
||
|
5. Industrial Design:
|
||
|
Design was needed for multiple units!
|
||
|
Basic idea is ok.
|
||
|
|
||
|
6. KICAD Design
|
||
|
Schematic:
|
||
|
Schematic does not load - you did not export the project properly
|
||
|
|
||
|
PCB:
|
||
|
No PCB Found.
|
||
|
|
||
|
7. Pricing / BOM / Assembly
|
||
|
No BOM submitted
|
||
|
Pricing is too optimistic. Sensor cost is not mentioned?/
|