A half-bridge inverter was designed using Infineon's IGLD60R190D1 CoolGaN and 2EDF7275K EiceDriver. The configuration can handle voltages up to 400V and currents up to 6A, occupying a footprint of 4278 sq. mm.
Go to file
Abhinav Chinnusamy 126dfc8b0d
Update README.md
2023-04-15 23:40:49 +05:30
Documentation changed GD Symbol 2023-01-31 13:10:27 +05:30
Footprints&symbols added logo 2023-03-10 09:10:08 +05:30
Half_Bridge_Inverter-backups renamed the files 2023-04-15 23:35:49 +05:30
bom renamed the files 2023-04-15 23:35:49 +05:30
power_board renamed the files 2023-04-15 23:35:49 +05:30
Half_Bridge_Inverter.kicad_pcb renamed the files 2023-04-15 23:35:49 +05:30
Half_Bridge_Inverter.kicad_prl renamed the files 2023-04-15 23:35:49 +05:30
Half_Bridge_Inverter.kicad_pro renamed the files 2023-04-15 23:35:49 +05:30
Half_Bridge_Inverter.kicad_sch renamed the files 2023-04-15 23:35:49 +05:30
README.md Update README.md 2023-04-15 23:40:49 +05:30
Schematic.pdf renamed the files 2023-04-15 23:35:49 +05:30
fp-info-cache renamed the files 2023-04-15 23:35:49 +05:30
ibom.config.ini renamed the files 2023-04-15 23:35:49 +05:30

README.md

for commits on or before Mar 10 2023, the main folder should be renamed as RnD_6th_sem when opened with KiCad.